Abstract: Abstract: This paper introduce control requirement for RO and high pressure pump ,sketch the principle and inner important parameters. According to the characteristics for RO system and the high pressure pump performance curve , adjust inner parameters of transducer, direct starting High pressure pump, RO system is smooth running. Transducer Control High pressure pump and cancle Electronically VALVE is able to fulfill RO requirements